The smart Trick of Dp50rb login That Nobody is Discussing
The smart Trick of Dp50rb login That Nobody is Discussing
Blog Article
1.2.two Warning Labels Warning Labels This means You should carefully read this guide prior to use gadget. The subsequent labels are a. Usually do not location the device on the sloped area. Otherwise the offered once the process product could slide, leading to personal personal injury or even the system functions Along with the cell malfunction.
The person just isn't permitted to open the handles and panel of your program, neither Notice: device disassemble is allowed. To ensure the system functionality and basic safety, only Mindray engineers or engineers licensed by Mindray can carry out maintenance.
Get an entire and extended see with the anatomical construction as a result of panoramic imaging coupled with velocity indicator and forward/backward scan skill generating scanning less difficult, smoother and even more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Click on Concur and Carry on to simply accept cookies and go on to the website or click on More info to view in depth descriptions of the kinds of cookies and decide on no matter if to simply accept specified cookies while on the internet site.
Articles Process Test the battery periodically : a) Examine if battery could be billed Generally when electric power-on: That the current ability is a hundred% or capability raises just after a brief time suggests the battery is often billed normally.
The chapter supplies the tactic to validate main function and effectiveness of item. That is only employed for reference, not preventive execution. Purpose examining and tests of this part shall be performed by Mindray provider engineers and also the user with each other. Website page 66: Standard Examination
Find out superior diagnostic info by extended see of the anatomical construction on all convex probes.
Evaluating people in currently’s demanding ecosystem needs impressive engineering that allows clinicians to help make speedy and self-confident diagnoses. The flexibility in the DP-fifty expands your clinical utility although assisting to increase affected person treatment.
5.2.three Geometric positioning accuracy Longitudinal geometric positioning accuracy Examination Move: Do changes as how in testing the utmost depth. Report the space by 20mm Each and every segment to the longitudinal targets line using the measurement caliper; Select the value with the best mistake (to 20mm), determine the accuracy utilizing the system below The measurement caliper must be positioned on the upper fringe of the goal, Notice:... Website page 79 Transverse geometric positioning precision Check Phase: Deal with the scan surface area of the phantom with h2o or couple gel, Carefully contact the probe While using the scan surface area Regulate the depth, building the transverse targets to be displayed while in the impression. Alter the main target level to generally be posited beside the transverse targets (the conventional is not really apparent) Alter parameters like get, TGC, earning Each and every transverse targets to get Evidently exhibited. Site 80 five.5.two.four Blackout Region Check Action: Cover the scan surface with the phantom with h2o or pair gel, gently Get in touch with the probe Along with the scan surface area Change the depth at a decrease value, and established the focus at the closest destination to the scan surface area. Lower the value of parameters like AP, Get right until the qualifications sound just may be observed. Webpage eighty one: Software Improve And Servicing
The DP-50 Expert is surely an modern, substantial-general performance Ultrasound System engineered that will help you get the insights you'll need. The Method’s powerful motor and significant-pace processing offer exceptional image high-quality and a complete information administration Remedy.
Find greater diagnostic data by means of extended perspective with the anatomical construction on all linear probes
Efficiency Test five.5.1 Test Course of action Resolution Detection depth Geometric Placement Precision Blackout spot check History the Examination images 5.five.2 Take a look at Material The impression utilized here is only for reference, keep on with the image result in the real Be aware: situation. Requirements: Exhibit: established the distinction and brightness with the scientific application worth (or perhaps the default position) Operation setting: dim room, simulating the clinical application setting. Page 76 In problem that the transverse resolution testing targets are horizontally shown, file the small length of two targets that can be clearly acknowledged. Repeat the operation previously mentioned for that transverse resolution screening targets at other depths. As proven in determine underneath. Axial resolution ... Web page seventy seven When using the convex probe, continue to keep the transverse resolution screening targets to notice: be exhibited near the midline. When utilizing a linear probe with steer operate, tend not to activate the steer operate when perform the transverse resolution examination. Zoom while in the area in which the targets located if necessary. The diameter of the concentrate on point at a specific depth is equivalent for Dp50rb the transverse resolution in the depth. Web page seventy eight 5.
Your Instrument for further biopsy: allowing adjustments on the scan line to get much better visibility on the needle, nerves and compact vessels, guaranteeing the continuity of all knowledge.
Notice: Be sure that you could potentially pull out and force into your IO board sockets vertically when pulling out and assembling the IO board assembly over the situation of the manage. Clear away panhead screws with washers M3X6 (4) utilized to safe the IO board, and after that you may get out the IO board. Webpage 116 Take away panhead screws with washers (2 M3X6) which are set on the main unit, acquire out the higher baffle and afterwards pull out two cables connecting the key board to the power module assembly.